Tender For supply, delivery, fixing testig and trial run of 20 hp inline booster for 150 mm dia distrubution line along with new 415 volts 50 hz control switch gear panel board for operationg above pump set, ms chamber, ms suction, delivery connections at chainna golkonda to supply water to bahadurguda and lakshmi tanda villages and also provide extra water to fulfill the supplies udner shamshabad section, eam cell iv, operation and maintenance division-xviii manikonda
Tender For corrigendum : supply of spare of lt vfd at hurl sindri on oem basis - dual temperature transmitter, filter capacitor for sine wave filter, current transformer ratio - 100/1a, vfd control device, vfd power device, hrc fuse link bs type, fuse holders & isolating link, hrc fuse bs type, fuse-link rating-80a, ac 690 v., fuse base nh din type, "6"" output filter ral 7035 size 6 incfan failure and temp detection unitiop (intelligent operator panel)power contactor rating-45a, 230v ac", "sine wave filter reactor rating -22kwpanel fanmulti-function meter (mfm)32-50 a, thermal overload relay""", circuit breaker with electronic trip, panel door mounted rotary op. handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, 5a, d series ac drm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs-4-20ma, motor restart timer, green push button & contact block, red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block., yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For corrigendum : supply of locking motor 24v dc , limit switchs for electric lifting barrier , rotary switch suitable for lc gate panel , octagonal boom in 4 sections fabricated from gi sheets , boom lock solenoid coil
Tender For corrigendum : supply of big limit switch in lock , lc gate operating panel lamp red , lc gate operating panel lamp yellow , lc gate operating panel lamp green , motor 24vdc for electric lifting barrier
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required
Tender For supply of sensor cable part no. ac505027 , dry chemical powder part no. ac42511001 , co2 expellant gas cartridge 300 gm part no. acfz11002 , actuation device part no. acfz11001 , dust cap for nozzle part no. acfz14010 , safety clip part no. acfz12007 , expellant gas cartridge 200gm part no. ac501025 , dcp cylinder 15 kg part no. ac502014 , nozzle conical brass part no. acfz13008 , horn unit for zone wise part no. acfz22002 , rupture disc assembly part no. ac505032 , lugs with fuse part no. acfz24006 , sensor end assembly for zone wise part no. acfz23003 , hp hose assy,half inch 4 long for zone wise part no. acfz19204 , hp hose assy,half inch 5 long for zone wise part no. acfz19205 , hp hose assy,half inch 7 long for zone wise part no. acfz19207 , hp hose assy,half inch 9 long for zone wise part no. acfz19209 , hp hose assy,three fourth inch 5 long for zone wise part no. acfz59305 , hp hose assy,three fourth inch 7 long for zone wise part no. acfz59307 , hp hose assy. one fourth inch 30 long part no. acfz18130 , hp hose assy. one fourth inch 9.5 long part no. acfz18109 , mounting block for hoses part no. ac507065 , three fourth inch hose assly. 4000mm part no. ac506057 , three fourth inch hose assembly 9ft part no. ac506056 , hp hose assembly one fourth inch 33 inch long part no. ac506037 , sticker set part no. ac509069 , hp hose assy one fourth inch 17 ft long part no. ac5060361 , cyl cap pneumatic,manual operation part no. ac502023 , harness cable assembly with connector part no. acfz21001 , control panel asm. for two zone system part no. acfz29222 , zone selector switch part no. acfz69222 ) /bid number : gem/2026/b/7400143 * /dated: 27-04-2026 & & / bid document 1 / 28
Tender For supply of flood light 100w d d - northwest nowa switch 6a , northwest nowa socket 6a , northwest nowa switch 16a , northwest nowa socket 16a , northwest nowa plate with frame 2m , northwest nowa plate with frame 3m , northwest nowa plate with frame 4m , northwest nowa plate with frame 6m , northwest nowa plate with frame 8m , northwest nowa plate with frame 12m , 3m pvc modular surface box , 6m pvc modular surface box , 8m pvc modular surface box , northwest nowa blanking plate 1m , 6a 3pin plug top , 16a 3pin plug top , dp encloser 2way metal , tpn encloser metal , pvc batten 20mm , pvc batten 25mm , 18 or 20 w led batten light 4 feet , 10 or 12 w led batten light 2 feet , fan regulator step type 1m , fan regulator step type 2m , pvc tape self adhesive pvc electrical insulation tape pack of 30 rolls , ht tape roll 9 meter , led down lighter 18 watt surface smd type , led down lighter 18 watt recess smd type , led panel light 2 x 2 36 watt , flood light 100 w , 2core1.5 sqmm flexiable cable
Tender For supply of switch and fuse test panel 415v,230v,24v,lamp and fuse testing panel,accessories and installation material,obs-fuse link-control ckt,obs-fuse link-powerckt,obs-indicating lamp,obs-dp on-off switch,230v,obs-tp on-off switch,415v,obs-dp mcb,24v dc,documentation of hard copy,documentation of soft copy